Commercial Heating And Cooling Heat Pump

Product Overview

 

Engineered for large-scale commercial buildings and industrial HVAC systems, these air-source heat pumps provide simultaneous or independent chilled and hot water supply. Utilizing modular architecture and multi-compressor staging, the units deliver precise thermal management across ambient temperatures from -25°C to 43°C.


Cooling Capacity Range: 65 kW to 1300 kW (Modular expandable up to 16 units)
Heating Capacity Range: 70 kW to 1400 kW
Refrigerant Options: R410A / R32 / R290 (Low GWP variants available)
Engineering Standard Compliance: Designed to meet Eurovent, AHRI 550/590, and ErP Lot 1/21 seasonal efficiency benchmarks.

 
 

Product Range

 

Engineering Selection Matrix for Mechanical Contractors (BIM/Revit files and submittal packages available upon request). 

 

Model Series

Function

Nominal Cooling Capacity

Nominal Heating Capacity

Compressor Type

Primary Application

HCA-M Series

Cooling & Heating

65 kW - 260 kW

70 kW - 280 kW

Hermetic Scroll (Dual/Quad)

Mid-size Offices, Hotels

HCA-S Series

Cooling & Heating

280 kW - 1300 kW

300 kW - 1400 kW

Semi-hermetic Screw

Large Commercial Complexes, Hospitals

HCA-H Series

High-Temp Heating

80 kW - 400 kW

85 kW - 430 kW

Enhanced Vapor Injection (EVI) Scroll

District Heating, Industrial Process

 

Technical Specifications

 

Specification

Details

Product Type

Commercial Heating and Cooling Air Source Heat Pump

Application Range

Large Commercial Buildings, Industrial HVAC Systems, District Heating, Process Cooling

Cooling Capacity Range

65 kW to 1300 kW

Heating Capacity Range

70 kW to 1400 kW

Modular Connection Capacity

Expandable up to 16 units

Refrigerant Options

R410A / R32 / R290 (Low GWP variants available)

Engineering Standards

Eurovent, AHRI 550/590, ErP Lot 1/21

Power Supply

380V-415V / 3Ph / 50Hz or 460V / 3Ph / 60Hz

Ambient Temperature Range (Cooling)

-15°C to 48°C

Ambient Temperature Range (Heating)

-25°C to 24°C

Maximum Leaving Water Temperature

55°C (Standard) / 65°C (High-Temperature EVI Version)

Compressor Type

Hermetic Scroll / Semi-hermetic Screw Compressors

Compressor Brands

Bitzer / Copeland

Compressor Configuration

Dual / Quad Scroll or Multi-Compressor Parallel Configuration

Heat Exchanger Type

Shell-and-Tube or AISI 316 Stainless Steel Brazed Plate Heat Exchanger

Heat Exchanger Insulation

25 mm Closed-Cell Elastomeric Foam

 

 
Key Features
 
01/

EVI Technology for Low-Ambient Operation: Enhanced Vapor Injection scroll compressors combined with an auxiliary sub-cooler maintain 100% heating capacity at -12°C ambient and operational output down to -25°C.

02/

Modular Multi-Circuit Redundancy: Units integrate 2 to 4 independent refrigeration circuits. If one circuit undergoes maintenance, remaining circuits maintain baseline system operation, eliminating single-point catastrophic failure.

03/

Intelligent Defrost Logic: Dynamic defrost algorithms monitor ambient humidity, coil temperature, and running duration to initiate defrost cycles only when frost accumulation impacts thermal exchange, minimizing heating interruptions.

04/

BMS Integration & Open Protocols: Onboard programmable logic controllers (PLC) support standard RS485 ports with Modbus RTU, BACnet MS/TP, and TCP/IP protocols for seamless central Building Management System integration.

 

 

productcate-500-500

 

Technology & Working Principle

Refrigeration Cycle Mechanics: The system operates on a standard vapor-compression cycle. During cooling, the heat exchanger acts as an evaporator, absorbing heat from building chilled water loops and rejecting it via outdoor condensers. In heating mode, a 4-way reversing valve switches refrigerant flow, extracting latent heat from ambient air down to -25°C and transferring it to the hydronic heating loop.


Capacity Modulation: Multi-compressor parallel configurations and inverter-driven fan staging allow multi-stage capacity modulation (25% - 50% - 75% - 100%), maintaining chilled water temperature within +/- 0.5°C of setpoint and avoiding frequent compressor cycling.

 

Applications

 

1

Commercial Real Estate:

Multi-tenant office buildings requiring simultaneous zonal cooling and heating via flexible 2-pipe or 4-pipe hydronic setups.

2

Hospitality (Hotels & Resorts)

Continuous domestic hot water pre-heating combined with guest room climate control, utilizing heat recovery options to recycle waste condenser heat.

3

Healthcare Facilities

Hospitals and laboratories demanding strict temperature stability and redundant backup circuits for critical cleanroom HVAC loops.

4

Light Industrial & Data Centers

Process cooling loops requiring 24/7 continuous year-round operation under high thermal loads.

 

 

System Solutions

Hydronic Schematic Integration: Fully compatible with primary-secondary pumping loops, variable primary flow (VPF) setups, and thermal storage buffer tanks.


Hydraulic Module Options: Available with factory-installed dual inverter-driven water pumps (duty/standby configuration), expansion vessels, flow switches, and safety pressure relief valves, drastically minimizing on-site mechanical piping labor.

productcate-500-500

 

OEM & ODM Customization

Structural & Material Adaptations:

Corrosion Protection

Blue-fin or hydrophilic gold-fin coil coatings with epoxy-coated casing panels built for coastal or heavy industrial environments.

01

Refrigerant Tailoring

Configurations optimized for R32, R454B, or low-GWP natural refrigerants like R290.

02

Acoustic Treatment

Enclosed compressor acoustic jackets and low-RPM fan blades to achieve sound pressure levels under 58 dB(A) at 10 meters.

03

Branding & Control Customization

Private-label sheet metal stamping, custom HMI touch-screen graphic overlays, and proprietary PLC logic programming.

04

 

Quality Control

 

 

Factory Testing Protocols:
Pressure Testing: Every refrigeration circuit undergoes nitrogen pressure testing at 3.2 MPa and helium leak detection.
Run-Test Facility: 100% of assembled units undergo full-load hot testing in psychrometric test chambers simulating ambient conditions from -20°C to 45°C prior to factory dispatch.


Compliance & Certifications:
Manufactured under ISO 9001 Quality Management and ISO 14001 Environmental Management standards.
Electrical safety and performance conformity compliant with CE (PED/LVD/EMC), Eurovent, and ETL/UL regulatory requirements.

 

FAQ

 

Q: What is the COP degradation curve of the unit at -15°C ambient temperature?

A: At an ambient temperature of -15°C and a leaving water temperature of 35°C, the standard EVI model maintains a heating COP between 2.1 and 2.4. Full test curves across various ambient and water temperatures are available in our downloadable Engineering Technical Manual.

Q: Can these units be installed in parallel for large district or campus-style HVAC loads?

A: Yes. Up to 16 identical or mixed modular units can be linked together under a single master controller using a CAN-bus network, allowing automatic lead-lag rotation and total load balancing.

Q: What is the standard lead time for standard catalog units vs. customized OEM orders?

A: Standard catalog units (380V/50Hz) typically ship within 25 to 30 business days. Custom OEM builds, specific refrigerant requirements, or special coastal corrosion packages require 45 to 60 business days following engineering drawing sign-off.

Q: What technical documentation is supplied with each shipment?

A: Each shipment includes comprehensive documentation: an Installation & Operation Manual (IOM), electrical wiring diagrams, hydraulic schematic drawings, factory test run reports, and CAD/BIM (Revit) files.

 

modular-1
Request a Quote & Submittal Package

Heading: Request an Engineering Quotation & BIM Files
Form Callout: To receive a detailed technical proposal, submittal package, and BIM/Revit files tailored to your HVAC project, please provide your parameters:
Required Cooling/Heating Capacity (kW or Tons) or Building Floor Area
Design Ambient Temperature & Target Water Flow/Return Temperatures
Power Supply Specifications (Voltage / Phase / Frequency)
Preferred Refrigerant and Certification Requirements (CE, ETL, Eurovent)
Action Button: Submit Project Parameters & Request Submittal Package

As one of the most professional commercial heating and cooling heat pump manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to wholesale customized commercial heating and cooling heat pump from our factory.

auxiliary heating and cooling heat pump, excellent heating and cooling heat pump, new installation heating and cooling heat pump