Commercial Inverter Heat Pump

Commercial Inverter Heat Pump

Monobloc air-to-water heat pump engineered for commercial hydronic space heating, cooling, and central sanitary hot water systems.
Send Inquiry
Description

Monobloc air-to-water heat pump engineered for commercial hydronic space heating, cooling, and central sanitary hot water systems. Utilizes full DC inverter modulation and Enhanced Vapor Injection (EVI) scroll compression to deliver rated thermal capacity in ambient conditions down to -25°C. Designed for mechanical contractors and HVAC system integrators requiring modular high-capacity thermal plant solutions compliant with EN 14511 and ErP Lot 1 regulations.

 

Technical Specifications

 

Parameter

Unit

Model: CIP-60KW

Model: CIP-120KW

Model: CIP-180KW

Heating Capacity (Air +7°C, Water 35°C)

kW

60.5

121.0

181.5

COP (Air +7°C, Water 35°C)

-

4.45

4.42

4.40

Heating Capacity (Air -7°C, Water 35°C)

KW

52.0

104.2

156.5

COP (Air -7°C, Water 35°C)

-

2.85

2.83

2.81

Cooling Capacity (Air 35°C, Water 7°C)

KW

54.0

108.0

162.0

EER (Air 35°C, Water 7°C)

-

2.95

2.92

2.90

Max Water Outlet Temperature

°C

60

60

60

Ambient Operating Range

°C

-25 ~ +43

-25 ~ +43

-25 ~ +43

Compressor Type & Qty

-

EVI Scroll × 1 (Dual Circuit)

EVI Scroll × 2

EVI Scroll × 3

Refrigerant / Charge Mass

-

R32 / 9.5 kg

R32 / 19.0 kg

R32 / 28.5 kg

Sound Pressure Level (1m)

DB(A)

<= 58

<= 61

<= 63

Electrical Supply

-

380V-415V / 3Ph / 50Hz

380V-415V / 3Ph / 50Hz

380V-415V / 3Ph / 50Hz

Hydraulic Connection Size

Inch

DN50 (2")

DN65 (2-1/2")

DN80 (3")

Dimensions (L × W × H)

Mm

2250 × 1120 × 1850

3900 × 1120 × 1850

4500 × 1120 × 1850

Net Weight

Kg

480

890

1250

 

Key Features

 

EVI Scroll Compression: Intermediate vapor injection circuit increases refrigerant mass flow at low suction pressures, preventing discharge temperature spikes at -15°C ambient.

Modular Multi-Unit Cascading: Master-slave bus controller links up to 16 parallel units (total 2,880 kW output) with automatic runtime equalization and load staging.

Acoustic Isolation Assembly: Dual-density vibration absorbers mounted on compressor baseframes; internal cabinet lined with 30mm sound-absorbent melamine foam.

Dynamic Frost Detection: Multi-sensor array tracks evaporator coil temperature, ambient dew point, and net operating time to trigger reverse-cycle defrost only when coil airflow impedance exceeds threshold.

 

Technology & Performance

 

EVI Refrigerant Injection Loop Principle
Low Suction Pressure (-20°C) passes through the Plate Heat Exchanger (Economizer) to produce Sub-cooled Liquid entering the Expansion Valve, while simultaneously feeding Intermediate Vapor Injection directly into the Scroll Compression Chamber, stabilizing discharge temperature below 105°C.
Inverter Modulation Logic
Brushless DC (BLDC) inverter compressor modulates rotational speed from 20 Hz to 120 Hz, matching real-time building thermal load fluctuations and eliminating 50Hz/60Hz start-up current surges. 

 

Applications

 

District Central Heating: Multi-family residential complexes and municipal heating networks.

Hospitality Infrastructure: Hotels, resorts, and athletic complexes requiring simultaneous domestic hot water (60°C) and four-pipe hydronic climate control.

Institutional Facilities: Schools, universities, and healthcare centers utilizing fan-coil units (FCU) and air handling units (AHUs).

Industrial Pre-Heating: Low-temperature process water loops and agricultural greenhouse climate control.

 

System Solutions

 

Typical multi-unit cascade configuration for a 500 kW mechanical room installation:

 

Outdoor Ambient Air feeds multiple parallel units (Unit 1 180kW, Unit 2 180kW, Unit 3 140kW), converging into a Common Header Pipe (DN100), passing through a Plate Heat Exchanger / Buffer Tank, and distributing into the Primary/Secondary Hydronic Building Loop.

 

Hydraulic Layout: Configured with primary-secondary variable-flow pumping loops, hydraulic separator/buffer tank, and 3-way motorized diverting valves for sanitary hot water priority.

Control Architecture: Central master controller manages lead/lag rotation based on operating hours and real-time return water temperature sensor input.

 

OEM & ODM Customization

 

Enclosure Materials: Structural frame in hot-dip galvanized steel; exterior panels available in powder-coated galvanized sheet or grade 304/316 stainless steel for marine environments.

Refrigerant Variants: Factory engineering validation available for R32, R290 (Propane), or R454B based on local environmental quota regulations.

Hydraulic Module Integration: Factory-fitted internal components including Wilo/Grundfos inverter circulation pumps, ASME/PED certified safety valves, and expansion vessels.

Controller Firmware: Customized Modbus address mapping, OEM brand splash screens, and localized HMI language packages.

 

Quality Control

 

Component Screening: Copper tube spectral analysis; compressor electrical winding resistance and insulation breakdown tests prior to chassis mounting.

Helium Mass Spectrometry: Refrigerant circuits pressurized to 3.0 MPa with helium gas; leak detection verified to tolerance threshold of 1 x 10^-7 Pa·m³/s.

100% Psychrometric Run-Test: Every assembled unit undergoes a 4-hour automated test cycle in psychrometric chambers from -25°C to +43°C, validating electrical input, thermal output, and vibration spectra.

Regulatory Compliance: ISO 9001, ISO 14001, CE-KEYMARK, ErP Efficiency Class A+++ (35°C outlet), and ETL listing.

 

FAQ

 

Q: What is the rated heating capacity retention at -15°C ambient?

A: Due to the EVI scroll architecture, the unit retains approximately 78% of its nominal +7°C heating capacity at -15°C ambient without electric resistance backup.

Q: How does the defrost cycle avoid cooling the main hydronic loop?

A: The reverse-cycle 4-way valve isolates the external evaporator coil while a closed-loop internal bypass prevents cold refrigerant from draining thermal energy out of the primary buffer tank during defrost intervals.

Q: What is the protocol for integrating units into a third-party Siemens/Johnson Controls BMS?

A: Each unit incorporates an RS485 serial port with open Modbus RTU register maps, allowing direct polling of temperatures, operating states, flow switches, and fault history.

Q: What spare parts are maintained for overseas project support?

A: Critical wear parts (electronic expansion valves, PCB inverter drive modules, dual-temperature sensors, and flow switches) are stocked for dispatch within 48 hours.

 

Request a Quote

 

To request technical proposal documentation, CAD drawings, or project-specific selection software outputs, submit the following parameters to our engineering team:

Design total thermal load requirements (kW)

Minimum winter ambient design temperature (°C)

Required water supply / return design temperatures (°C)

Local electrical grid standard (Voltage / Phase / Frequency)

Target certification standard (CE, ErP, ETL)

Hot Tags: commercial inverter heat pump, China commercial inverter heat pump manufacturers, suppliers, factory, air circulation heating and cooling heat pump, climate control heating and cooling heat pump, energy saving heating and cooling heat pump, fresh air supply heating and cooling heat pump, indoor heating and cooling heat pump, standards compliant heating and cooling heat pump