Split Air Source Heat Pump

Split Air Source Heat Pump

Engineered for European and North American retrofit and new-build residential projects, this split system separates the outdoor condensing unit from the indoor hydraulic module.
Send Inquiry
Description

Engineered for European and North American retrofit and new-build residential projects, this split system separates the outdoor condensing unit from the indoor hydraulic module.


System Architecture: Two-piece layout connecting outdoor unit and indoor hydrobox via refrigerant lines, eliminating outdoor water pipe freezing risks during sub-zero grid outages.
Refrigerant Options: Low-GWP R32 and natural refrigerant R290 (Propane).
Energy Ratings: ErP A+++ certified at 35 deg.C water outlet; ErP A++ at 55 deg.C water outlet.

 

Product Range & Specifications

 

Model Series

Heating Capacity (kW)

Power Supply

Refrigerant

Max Water Temp

Target Application

SPLIT-06V

4.0 - 6.0 kW

220-240V/1Ph/50Hz

R32 / R290

60 deg.C / 75 deg.C

Small Apartments, Low-energy Homes

SPLIT-10V

6.0 - 10.0 kW

220-240V/1Ph/50Hz

R32 / R290

60 deg.C / 75 deg.C

Detached Residential Villas

SPLIT-16V

12.0 - 16.0 kW

220-240V/1Ph or 380V/3Ph

R32 / R290

60 deg.C / 75 deg.C

Large Residences, Light Commercial

SPLIT-20D

18.0 - 22.0 kW

380V/3Ph/50Hz

R32

60 deg.C

Multi-family Retrofits, Commercial Space

 

Technical Specifications

 

Technical Parameter

Specification Details

Compressor Technology

Full DC Inverter Rotary / EVI Scroll

Water Circulating Pump

Integrated high-efficiency ECM pump (EEI <= 0.20)

Plate Heat Exchanger

AISI 316 Stainless Steel Brazed Plate Heat Exchanger

Operating Ambient Range

Heating: -25 deg.C to +43 deg.C / Cooling: +10 deg.C to +48 deg.C

Acoustic Level

<= 42 dB(A) sound pressure at 1 meter in Silent Mode

Communication Interface

Standard Modbus RTU protocol for BMS and external thermostat integration

 

Key Engineering Features

 

EVI Technology: Injects intermediate-pressure refrigerant vapor into the compression chamber, maintaining 100% nominal heating capacity down to -15 deg.C ambient, with stable operation at -25 deg.C.

Dual-Zone Control: Independent control channels manage two separate thermal emission circuits simultaneously (e.g., floor heating loops at 35 deg.C and high-temperature radiators at 50 deg.C).

Dynamic Defrosting: Real-time monitoring of coil temperature, ambient humidity, and runtime cycles to initiate defrosting only upon actual frost accumulation.

Smart Grid & PV Integration (SG Ready): Hardware contacts prioritize self-consumed PV solar energy or switch operation based on low-tariff utility signals.

 

Technology & Working Principle

 

Physical Layout:

Outdoor Unit: Inverter compressor, DC fan motor, electronic expansion valve (EEV), hydrophilic blue-fin evaporator coil.

Indoor Hydrobox: Brazed plate heat exchanger, water pump, safety relief valve, air vent, expansion vessel, controller board.

Thermodynamic Cycle: Closed-loop vapor-compression cycle transferring latent heat from ambient air to the indoor water loop. Water circulation remains strictly inside the conditioned indoor hydrobox.

 

Typical Applications

 

Underfloor Heating & Cooling: Low-temperature water distribution (30 deg.C to 35 deg.C) maximizing seasonal efficiency (SCOP).

Radiator Boiler Retrofits: Direct drop-in replacement for traditional oil/gas boilers, supplying stable 55 deg.C water without modifying existing radiators.

Domestic Hot Water (DHW) Integration: Three-way valve integration with DHW storage cylinders, supporting anti-Legionella disinfection up to 70 deg.C.

Hybrid Systems: Compatible with solar thermal arrays and backup gas/electric boilers.

 

System Solutions & Architecture

 

Hydraulic Configuration A (Space Heating + Buffer Tank):

Split Heat Pump -> Indoor Hydrobox -> Buffer Tank -> Manifold -> Underfloor Loops.

Hydraulic Configuration B (All-in-One DHW Setup):

Split Heat Pump -> Integrated Hydrobox with Built-in DHW Tank -> Multi-zone Mixing Valves.

Accessory Compatibility: Supports third-party zone valves, 0-10V mixing valves, and flow meters.

 

OEM & ODM Customization Options

 

Visual Branding: Custom sheet metal RAL colors, laser-etched/silk-printed logo, and customized boot UI layout on the LCD controller.

Software & Localization: Tailored Modbus register mapping, multi-language firmware (English, German, French, Polish, Italian, Spanish), and regional voltage variants (220V/380V/60Hz).

Component Tiering: Flexible selection options for compressors, pumps, and expansion valves upon request.

 

Quality Control & Manufacturing Standards

 

Testing Laboratories: Automated calorimeter test chambers built to ASHRAE 116 / EN 14511 standards, simulating conditions from -30 deg.C to +55 deg.C.

Production Line Protocols:

Helium Mass Spectrometry Leak Detection: 100% pressure testing of refrigerant circuits.

Electrical Safety Audit: High-voltage breakdown, earth continuity, and leakage current tests on every unit.

Hot Run-In Test: 100% online operational verification of compressor startup, 4-way valve switching, and sensor feedback.

Compliance Certifications: CE (LVD, EMC, RED), ErP Directive 2009/125/EC, RoHS, REACH, and ISO 9001.

 

FAQ

 

Q: What is the maximum water outlet temperature without auxiliary heating?

A: R32 split series delivers up to 60 deg.C; R290 series delivers up to 75 deg.C.

Q: How does the split configuration handle winter freeze protection?

A: Water lines remain inside the indoor hydrobox. The outdoor unit contains refrigerant only, preventing freeze damage during extended power outages.

Q: What technical compliance documents are supplied for European distribution?

A: CE, ErP, and PED certificates. Complete ErP data sheets and Keymark test reports are available for qualified partners.

Q: What is the standard production lead time for bulk OEM orders?

A: 35 to 45 days following deposit confirmation and artwork approval.

 

Request a Technical Quotation

 

Submit project parameters to receive formal pricing, data sheets, and CAD/BIM drawing files.


Required Inquiry Fields:
Full Name / Corporate Company Name / Business Email
Target Market / Country of Installation
Business Type: [ ] OEM Branding / [ ] Regional Distribution / [ ] Commercial Project Contracting
Estimated Annual Volume / Trial Order Quantity
Technical Requirements: Capacity (kW), Refrigerant, Voltage 

Hot Tags: split air source heat pump, China split air source heat pump manufacturers, suppliers, factory, adaptable heating and cooling heat pump, ductless heating and cooling heat pump, healthy heating and cooling heat pump, large scale heating and cooling heat pump, repeatable performance heating and cooling heat pump, smart heating and cooling heat pump