R32 Air Source Heating And Cooling Heat Pump

R32 Air Source Heating And Cooling Heat Pump

Monobloc air source heat pump utilizing R32 refrigerant (GWP 675) and DC inverter technology for hydronic underfloor heating, fan coil cooling, and domestic hot water supply.
Send Inquiry
Description

Monobloc air source heat pump utilizing R32 refrigerant (GWP 675) and DC inverter technology for hydronic underfloor heating, fan coil cooling, and domestic hot water supply. Designed to comply with European ErP energy efficiency regulations and F-gas phase-down timelines.
The outdoor monobloc architecture integrates the compressor, brazed plate heat exchanger, expansion valve, and water pump within a single enclosure, eliminating on-site refrigerant piping and lowering leakage risks. Operating envelope extends down to -25°C ambient temperature.

 

Product Range

 

Model

Nominal Heating (kW)

Nominal Cooling (kW)

Power Supply

Target Application

ErP Rating (35°C / 55°C)

HP-06-M32

6.2

5.8

220V-240V/1Ph/50Hz

Small Apartments, Retrofit Houses

A+++ / A++

HP-10-M32

10.5

9.8

220V-240V/1Ph/50Hz

Standard Single-Family Homes

A+++ / A++

HP-14-M32

14.0

13.2

380V-415V/3Ph/50Hz

Large Villas, Multi-room Hydronic

A+++ / A++

HP-20-M32

20.2

19.0

380V-415V/3Ph/50Hz

Light Commercial / Multi-family

A++ / A++

HP-30-M32

30.0

28.5

380V-415V/3Ph/50Hz

Commercial Buildings / Hotels

A++ / A++

 

Technical Specifications

 

Parameter Category

Technical Specification Data

Refrigerant

R32 (GWP 675, Zero ODP)

Compressor Type

DC Twin-Rotary / EVI Scroll (Inverter Driven)

Operating Ambient Temp

Heating: -25°C to 43°C

Max Water Outlet Temp

60°C (Without Electric Heater Backup)

COP Range (EN14511)

3.20 to 4.85 (A7/W35)

Sound Pressure Level

42 to 52 dB(A) at 1 meter (Night silent mode active)

Hydraulic Connection

1-inch to 1-1/4 inch BSP / NPT Male

Communication Protocol

Modbus RTU / RS485 (BMS & Smart Grid Integration)

Certifications

CE-LVD, CE-EMC, RoHS, ErP Keymark, MCS (Pending)

 

Key Features

 

EVI Vapor Injection: Maintains 80% heating capacity at -15°C ambient and delivers 60°C water output without electric heater backup.

Full DC Inverter Modulation: Stepless compressor and fan speed matching thermal load fluctuations to eliminate temperature swings.

Low Noise Architecture: Multi-layer acoustic foam compressor insulation and swept-wing DC fan blades complying with VDI 2058 noise limits.

Smart Grid & PV Ready: Built-in SG Ready contacts and photovoltaic matching logic for surplus solar thermal storage.

Anti-Freeze Protection: Automated pump cycling, thermistor monitoring, and plate heat exchanger self-drainage algorithms.

 

Technology & Working Principle

 

Operating on the reversed Carnot cycle:

Evaporation: Fin-and-tube evaporator absorbs low-grade ambient heat into liquid R32.

Compression: DC inverter compressor pressurizes vapor. EVI injects intermediate-pressure vapor into the chamber, sustaining mass flow at sub-zero temperatures.

Condensation: Brazed plate heat exchanger transfers thermal energy from high-pressure R32 gas to the water loop.

Expansion: Electronic expansion valve (EEV) meters refrigerant back to low pressure.

 

Applications

 

Residential Retrofits: Direct boiler replacement for low-temperature underfloor heating or high-efficiency radiators.

Multi-Zone Living: Centralized or cascading setups supplying independent thermal zones.

Light Commercial: Offices, retail spaces, and boutique hotels requiring seasonal space heating and fan-coil cooling.

 

System Solutions

 

System Architecture:

R32 Monobloc Heat Pump -> Buffer Tank / Hydraulic Separator -> Underfloor Heating Loops / Fan Coil Units / Domestic Hot Water Tank

Buffer Tank: Required for multi-zone setups to maintain minimum water volume and prevent compressor short-cycling.

DHW Priority: Automated 3-way valve control routing thermal output to domestic hot water cylinder coils.

 

OEM & ODM Customization

 

Enclosure & Branding: RAL powder coating colors, laser-engraved or silk-screened client logos, and custom casing geometry.

Software & UI: Multilingual display interfaces (English, German, French, etc.), boot logos, and custom Modbus register mapping.

Component Options: Alternate electrical specs (e.g., 208V/60Hz) and hydraulic component selections (Wilo/Grundfos, SWEP/Alfa Laval).

 

Quality Control & Testing Standards

 

Manufactured under ISO 9001 and ISO 14001 systems. Mandatory testing per unit:

 

Helium Leak Detection: Mass spectrometer testing of pressurized circuits (< 2 x 10^-7 Pa*m3/s).

Electrical Safety: Dielectric withstand voltage (1800V, 1s) and earth continuity testing.

Automated Run-Test: 100% factory run-test under simulated water and ambient conditions verifying pressure, superheat, and COP metrics.

 

FAQ

 

Q: What is the water output temperature at -10°C ambient?

A: Up to 55°C without electric heater backup, driven by EVI compressor technology.

Q: Does monobloc installation require F-gas certification?

A: The refrigerant circuit is factory-sealed and pre-charged. Only standard hydronic plumbing and electrical connections are performed on-site, minimizing F-gas technician requirements compared to split systems.

Q: What documentation is provided for subsidies?

A: Accredited EN 14511 test reports (TÜV/SGS), ErP data sheets, CE certificates, and KEYMARK database registration documents.

Q: What is the standard production lead time?

A: 30 to 45 days following approval of artwork, specifications, and deposit receipt.

 

Request a Quote

 

For data sheets, STEP 3D CAD models, or volume pricing, contact our engineering sales team.

Required Project Data: Target country, annual volume estimate, power supply (230V/400V), and accessory requirements.

Email: leo_heatpump@163.com

Hot Tags: r32 air source heating and cooling heat pump, China r32 air source heating and cooling heat pump manufacturers, suppliers, factory, air source heating and cooling heat pump, exclusive technology heating and cooling heat pump, healthy heating and cooling heat pump, pleasant heating and cooling heat pump, stable operation heating and cooling heat pump, standards compliant heating and cooling heat pump