The Monoblock Air Source Heat Pump is an integrated DC inverter monoblock air source heat pump for space heating, cooling, and domestic hot water (DHW). The outdoor cabinet houses the inverter compressor, plate heat exchanger, circulation pump, and expansion vessel in a single chassis, eliminating refrigerant pipe routing inside the building.
Refrigerant: R290 (Propane, GWP = 3)
Energy Efficiency: ErP A+++ rating (W35C / W55C)
Operating Limit: Ambient temperature down to -25C
Max Leaving Water Temperature: 75C for high-temperature radiator retrofitting
Product Range
|
Model |
Heating Capacity (A7/W35) |
Cooling Capacity (A35/W7) |
Power Supply |
Dimensions (W x D x H, mm) |
Net Weight |
|
MB-06-R290 |
6.0 kW |
5.5 kW |
230V / 1Ph / 50Hz |
1110 x 480 x 865 |
115 kg |
|
MB-09-R290 |
9.0 kW |
8.2 kW |
230V / 1Ph / 50Hz |
1110 x 480 x 865 |
120 kg |
|
MB-12-R290 |
12.0 kW |
11.0 kW |
400V / 3Ph / 50Hz |
1290 x 490 x 1420 |
165 kg |
|
MB-16-R290 |
16.0 kW |
14.5 kW |
400V / 3Ph / 50Hz |
1290 x 490 x 1420 |
175 kg |
Technical Specifications
|
Technical Parameter |
Specification Detail |
|
Test Standards & Compliance |
EN 14511, EN 14825. Certified by EHPA KEYMARK, MCS (UK), CE-RED. |
|
Compressor & Inverter |
Hermetic DC inverter rotary/scroll compressor (Modulation range: 20 Hz to 100 Hz). |
|
Hydraulic Module |
PWM-controlled inverter wet rotor pump (Max head: 7.5 m) & 8L diaphragm expansion vessel. |
|
Flow Detection |
Differential pressure sensor and paddle flow switch. |
|
Acoustic Performance |
Sound pressure level: 42 dB(A) to 48 dB(A) at 1 meter (EN 12102). Silent mode: -4 dB(A). |
|
Electrical Protection |
IPX4 water resistance, phase sequence protection, overcurrent trip. |
Key Features
Low-GWP Refrigerant: R290 refrigerant complies with EU F-Gas regulations (GWP = 3, ODP = 0).
High Thermal Output: Delivers 75C leaving water at -10C ambient without auxiliary electric heaters.
Dynamic Modulation: Full DC inverter control adjusts compressor and fan speed continuously to match thermal load.
Frost Mitigation Logic: Automatically activates circulation pump and optional electric trace heating when ambient or water drops below +4C.
Smart Grid Compatibility: Standard Modbus RTU protocol with SG Ready inputs for photovoltaic (PV) and dynamic tariff integration.
Technology & Working Principle
Evaporation: Ambient air flows through the finned-tube evaporator; low-pressure liquid R290 absorbs thermal energy.
Compression: The DC inverter compressor raises refrigerant vapor pressure and temperature.
Condensation: Superheated R290 passes through the brazed plate heat exchanger (BPHE) to heat the hydronic loop.
Expansion: Electronic expansion valve (EEV) reduces refrigerant pressure and temperature before evaporator re-entry.
Distribution: Heated water circulates to buffer tanks, underfloor manifolds, or fan coil units.
Applications
Space Heating & Cooling: Underfloor heating, low-temperature fan coil units (FCUs), and panel radiators.
Domestic Hot Water: Integration with single or double-coil storage tanks via a 3-way diverter valve.
Boiler Retrofits: Direct fossil fuel boiler replacement for European residential heating upgrades.
System Solutions
Primary Circuit: Outdoor monoblock connected to an indoor buffer tank or hydraulic separator via insulated water pipes (with glycol antifreeze or isolation valves).
Secondary Distribution:
Circuit A: Underfloor heating via a motorized mixing valve.
Circuit B: High-temperature radiators via direct loop.
Circuit C: DHW tank via 3-way diverter valve.
Included Accessories: Flexible anti-vibration hoses, water return Y-strainer, 3 bar safety relief valve, wired room thermostat.
OEM & ODM Customization
Enclosure & Branding: Custom RAL sheet metal coloring, laser-etched front grille logo, localized user manuals.
Software & Controls: Customized HMI display language, private-label cloud app integration, and regional defrost algorithm tuning.
Hydraulic Options: Optional integrated booster pumps, secondary expansion vessels, and custom sensor calibrations.
Quality Control
Material Verification: Spectroscopic analysis of copper tubes and steel plate thickness checks.
Pressure Testing: Helium leak detection and 3.0 MPa nitrogen pressure holding test for 24 hours.
Electrical Testing: 1800V dielectric strength test (1s), earth continuity, and insulation resistance (>50 MOhm).
Automated Run Test: 100% factory testing on a water-enthalpy test bench simulating -25C to +43C ambient conditions for capacity, COP, and electrical draw verification.
FAQ
Request a Quote
Submit project parameters to obtain data sheets, 3D CAD files, container loading data, or OEM terms:
Required Quantity / Annual Volume:
Target Market / Destination Country:
Required Heating Capacity & Power Supply:
Application Type (New Build / Retrofit / OEM Branding):
[ Submit Inquiry / Contact Engineering Team ]
Hot Tags: monoblock air source heat pump, China monoblock air source heat pump manufacturers, suppliers, factory, building heating and cooling heat pump, consistent performance heating and cooling heat pump, cost effective heating and cooling heat pump, durable heating and cooling heat pump, exposed heating and cooling heat pump, heating heat pump

