Operating reliably down to -35°C ambient temperature, this R290 cold climate heat pump delivers space heating and domestic hot water in severe cold regions. Utilizing dual-stage rotary/scroll compression and EVI (Enhanced Vapor Injection) technology, the unit maintains over 80% of its rated heating capacity at -15°C and provides leaving water temperatures up to 75°C, serving as a high-efficiency solution for hydronic heating retrofits and low-carbon buildings.
Key Features
Sub-Zero Operation: Continuous heating output down to -30°C ambient without mandatory auxiliary electric heater intervention.
High-Temperature Water Delivery: Maximum leaving water temperature of 75°C, compatible with traditional high-temperature cast-iron and aluminum radiators for seamless retrofit projects.
Acoustic Silence: Multi-layer sound insulation enclosure, DC inverter fan motor, and floating compressor mounting limit sound pressure level to 42 dB(A) at a 3-meter distance.
Adaptive Defrost Control: Real-time coil temperature, humidity, and runtime algorithm minimizes defrost cycle frequency and duration.
Low GWP Refrigerants: Factory-charged with eco-friendly R290 propane or R32, fully compliant with international environmental regulations and F-gas directives.
Technical Specifications
|
Technical Parameters |
Model: NCH-12R (Single Phase) |
Model: NCH-18R (Three Phase) |
Model: NCH-24R (Three Phase) |
|
Heating Capacity (+7°C Ambient / 35°C Water) |
12.0 kW |
18.5 kW |
24.0 kW |
|
COP (+7°C Ambient / 35°C Water) |
4.65 |
4.58 |
4.52 |
|
Heating Capacity (-15°C Ambient / 35°C Water) |
10.2 kW |
15.6 kW |
20.5 kW |
|
COP (-15°C Ambient / 35°C Water) |
2.85 |
2.80 |
2.76 |
|
Max Leaving Water Temperature |
75°C |
75°C |
75°C |
|
Operating Ambient Temperature Range |
-35°C ~ +43°C |
-35°C ~ +43°C |
-35°C ~ +43°C |
|
Compressor Type |
EVI DC Inverter Rotary |
EVI DC Inverter Scroll |
EVI DC Inverter Scroll |
|
Refrigerant / Charge |
R290 / 1.4 kg |
R290 / 2.2 kg |
R290 / 2.8 kg |
|
Sound Power Level (EN 12102) |
52 dB(A) |
55 dB(A) |
57 dB(A) |
|
Power Supply |
220-240V/1Ph/50Hz |
380-415V/3Ph/50Hz |
380-415V/3Ph/50Hz |
|
Water Connection Size |
1-inch BSP |
1-inch BSP |
1.25-inch BSP |
|
Net Dimensions (W x D x H) |
1110 x 480 x 880 mm |
1150 x 520 x 1420 mm |
1150 x 520 x 1420 mm |
|
Net Weight |
135 kg |
185 kg |
198 kg |
Technology & Performance
EVI Twin-Injection Compression: An intermediate enthalpy-adding flash tank increases refrigerant mass flow rate at sub-zero temperatures, stabilizing discharge temperature and preventing compressor overheating.
Hydrophilic Blue-Fin Evaporator: Wide-pitch louvered fins with hydrophilic coating accelerate condensate drainage during defrost cycles to mitigate coil ice bridging.
Integrated Hydraulic Module: Incorporates a high-efficiency Wilo/Grundfos inverter circulation pump, expansion vessel, Alfa Laval/SWEP plate heat exchanger, and safety relief valve, reducing on-site installation time by 50%.
Smart IoT Controller: Modbus RTU and BACnet protocols enable seamless Building Management Systems (BMS) integration and remote diagnostics.
Applications
Residential Hydronic Heating: Stable low-temperature water delivery (35°C to 45°C) for underfloor heating loops and fan coil units in insulated homes.
Legacy Boiler Retrofits: Direct fossil-fuel boiler replacement by supplying high-temperature water (60°C to 75°C) to existing high-temperature radiator circuits.
Light Commercial Projects: Cascaded multi-unit configurations (up to 16 units in parallel) delivering up to 384 kW heating capacity for offices, retail spaces, and multi-family apartments.
OEM & ODM Customization
Structural Enclosures: Tailored cabinet dimensions, custom RAL powder-coating colors, and laser-etched private-label nameplates.
Hydraulic Integration: Optional integration of auxiliary electric heaters (3 kW to 9 kW), dual-zone mixing valves, or domestic hot water 3-way diverter valves.
Controller Branding: Customized boot logos, localized touchscreen UI languages, and proprietary API integration for regional cloud platforms.
Quality Control & Manufacturing Facility
Manufacturing Capacity: Produced in a 45,000 m² vertically integrated HVAC facility with an annual output of 50,000 units.
100% Helium Leak Testing: Executed on all refrigerant circuits and brazed joints under 3.0 MPa pressure.
Electrical Safety Verification: Dielectric withstand testing (3000V), earth continuity testing, and insulation resistance checks performed on every batch.
Acoustic & Performance Testing: Sound power level verification compliant with ISO 3744 standards, paired with full-load calorimeter climate simulation labs covering -35°C to +45°C operating points.
Certifications: CE-LVD, CE-EMC, ErP Energy Efficiency Label (A+++ at 35°C / A++ at 55°C), KEYMARK, and RoHS compliance.
Packaging & Shipping
Export-Standard Crating: Fumigation-free plywood crates with internal shock-absorbing EPE foam blocks and moisture-barrier vacuum packaging.
Transit Monitoring: Palletized units equipped with Shockwatch and tilt-watch indicator labels.
Logistics Efficiency: Optimized container loading (18 units per 40' High Cube container for standard outdoor chassis) with flexible FOB/CIF terms from major ports.
FAQ
Request a Quote
Call to Action: Submit project specifications (heating load, design ambient temperature, target standards) to receive a custom technical proposal, STEP/CAD drawings, and wholesale pricing within 24 hours.
[Button: Request Technical Proposal & Pricing]
Hot Tags: nordic cold climate heat pump, China nordic cold climate heat pump manufacturers, suppliers, factory, energy saving heating and cooling heat pump, first class heating and cooling heat pump, integrated heating and cooling heat pump, made to order heating and cooling heat pump, unique technology heating and cooling heat pump, zero emission heating and cooling heat pump